Is the lapping of bar done correctly?
Lap joint was done good but it seems all the bars are jointed at one location, if yes, then it is wrong, because 50% is max to lap at one location.
Sivasankar Reddy
Post #14
Jun 7, 2019
Forum:
Ask Question
Is it column lapping is correct? if not tell me what happened.
Sir, 1.Column lap was not provided properly as the lap rod to be placed up to joggles(crank). 2. Junction area lapping should not provide.
Sivasankar Reddy
Post #6
May 27, 2019
Forum:
Ask Question
Root cause of this bridge failure?
Cause of failure is water was flowed up to foundation bottom and the design of depth of foundation is less.
Sivasankar Reddy
Post #2
May 27, 2019
Forum: